28 November 2022

New 60 V Offset Power Rail Probes Offer the Capability Needed for 48 V Power Integrity Analysis

RP4060 Rail Probe
Figure 1. The RP2060 and RP4060
build on the legacy of the RP4030 power
rail probe. The new probes are ideally
suited to working with the new 48 Vdc 
power structures.
In 2016, Teledyne LeCroy first offered the RP4030 Power Rail Probe, which was designed to enable engineers to probe a low-impedance, low-voltage DC power/voltage rail signal without loading the device under test (DUT). It provided ±30 V of probe offset to allow a DC power/voltage rail signal to be displayed in the vertical center of the oscilloscope regardless of the gain (sensitivity) setting.

Recently, we released two, new power rail probes that build on those capabilities—the 2 GHz RP2060 and 4 GHz RP4060. Both probes feature:

  • ±60 V Offset Capability
  • ±800 mV Dynamic Range
  • 50 kΩ DC Input Impedance (for low loading of low-impedance power rails)
  • 1.2:1Attenuation (for low additive noise)
  • MCX-terminated cable with a variety of board connections: 4 GHz*-rated MCX PCB mount;
    4 GHz* solder-in; 3 GHz* coaxial cable to U.FL PCB mount; optional 500 MHz browser
* Bandwidths listed are for the 4 GHz RP4060. Maximum bandwidth when used with RP2060 is 2 GHz.

Why the New Probes?

One driver of the new release is the increase in the number and size of data centers needed to support cloud computing and other data-intensive applications, and the new power architectures they require. The new rail probe is designed to ideally meet the needs of engineers working with power rails rated up to 48 Vdc.

09 May 2022

Signal and Power Integrity Tutorial: Measuring Clock Jitter Sensitivity to Power Rail Noise, Pt. 2

Figure 1. 400 mVpp oscillation on the power trace is due to 48 MHz clock noise.
Figure 1. 400 mVpp oscillation on the power trace
is due to 48 MHz clock noise.

In Part 1, we used a function generator to create a power source with a known perturbation. Seeing that the noise on the power rail and the clock period were synchronous when we observed both traces together using a WavePro HD oscilloscope, we knew that there was a clear relationship between the two to be further investigated. Now, we're ready to examine more closely how the clock jitter responds to voltage variations on the power rail.

02 May 2022

Signal and Power Integrity Tutorial: Measuring Clock Jitter Sensitivity to Power Rail Noise, Part 1

Figure 1. Voltage variations on the power rail shown in the same grid as the clock period track (jitter track). These waveforms are the basis of the clock jitter sensitivity measurement. The inverse relationship between the jitter track and the power trace shows that the clock is sensitive to variations in rail voltage.
Figure 1. Voltage variations on the power rail
shown in the same grid as the clock period track
(jitter track). These waveforms are the basis of
the clock jitter sensitivity measurement. The
inverse relationship between the jitter track and
the power trace shows that the clock
is sensitive to variations in rail voltage.

In a previous post, we described A Robust Method for Measuring Clock Jitter with Oscilloscopes as variation in a clock signal’s period. Clock jitter is characterized by the standard deviation (sdev) of the clock period measurement. The track function of the clock period sdev shows us the variations in jitter over time, synchronous with the waveform source. 

In this post and the next, we’ll show how to make use of the clock period track function to match jitter variations to possible sources of jitter, in particular to voltage variations on the clock power rail. The offset voltage of a function generator powers a clock signal source. By creating a known variation in the function generator output, we can match that to the resulting clock jitter to calculate the clock jitter sensitivity to rail voltage changes. A known clock jitter sensitivity value can help you predict how a design will respond to rail voltage changes.

28 February 2022

Signal and Power Integrity Tutorial: A Robust Method for Measuring Clock Jitter with Oscilloscopes

Figure 1. Clock jitter measured as a variation of clock signal absolute period.
Figure 1. Clock jitter measured as a variation
of clock signal absolute period.
Clock jitter is the variation of a clock signal’s frequency or period. Either measurement carries the same information, but the period measurement is a simple time interval measurement easily performed using a real-time oscilloscope. If we have a robust way of measuring clock jitter, we have the basis for measuring the clock signal’s sensitivity to other features in the environment that can affect the period. Voltage noise on the power rail is just one external force that can affect clock jitter, which we'll show you how to measure in a future post.

In this post, we’ll demonstrate a robust method for measuring clock jitter using an example from Dr. Eric Bogatin’s webinar, “The Impact of Power Rail Noise on Clock Jitter.”  

The clock in our examples is a 5-stage ring oscillator which generates a square wave signal between 10 and 66 MHz. The test instrument is a WavePro HD 12-bit, 4-Ch, 8 GHz, 20 GS/s, 5 Gpts oscilloscope with 60 fs sample clock jitter.

In the process, we make a series of oscilloscope sample clock tests and timebase adjustments as  consistency checks. While measuring jitter is less about absolute accuracy than about the relative precision of measuring the time interval from cycle to cycle, a fundamental part of that is ensuring the absolute accuracy of the oscilloscope’s timebase.

09 November 2020

Fundamentals of Power Integrity: Mutual Aggressors and Rail Transient Response Measurement

Fig 1. Rail droop in response to a load step is a typical case of mutual aggressors in a PDN.
Fig 1. Rail droop in response to a load step is
a typical case of mutual aggressors in a PDN.
A third type of noise found in PDNs is what we call mutual aggressors, which is crosstalk coupling from one component of the PDN onto another.

An obvious example is a load step in the PDA, where something in the system being turned on pulls current from the VRM that supplies a rail. In Figure 1, you can see how the output voltage of the VRM supplying a 1 V rail droops in response to a load step before it recovers. This is still noise: it is a signal variation that we're not expecting and don't want.

We want to be able to characterize that noise, because too much droop could affect the operation of other components that are already consuming power from that device.

In order to do so, we’re going to measure the rail transient response to the load application. We need only look at two signals: the voltage and the current on the rail of interest. Figure 1 shows the voltage on C5 (the green trace) and the current on C8 (the orange trace).

02 November 2020

Your Ground Bounce Questions Answered

Figure 1. Line set to "quiet low" shows ground bounce occurring as I/O driver switches.
Figure 1. Line set to "quiet low" shows ground
bounce occurring as I/O driver switches.
During an October 2020 webinar, Don’t Let Ground Bounce RuinYour Day, Dr. Eric Bogatin was asked several questions regarding his topic of presentation. Here are his answers.

Q: From what frequency should we consider ground bounce to be a problem?

A: Ground bounce is really due to a dI/dt. Generally, it becomes a problem with rise times shorter than 100 ns. The bandwidth of this is about 3.5 MHz. This means ground bounce can be an issue at relatively low frequency.

21 September 2020

Fundamentals of Power Integrity: Board Pollution

Figure 1. "Pollution" occurring on PDN traces.
Figure 1. "Pollution" occurring on PDN traces.
Board pollution is noise occurring on the packages and interconnects (traces and planes) that carry current from the VRMs to the consumer devices.
One place it can originate is from the VRM itself, for example, with the switching noise the VRM generates (Figure 1). That can be a real concern if the board capacitance means you have a resonance around the switching frequency that would act as an amplifier for the switching noise and cause all kinds of problems with other devices on the board.

14 September 2020

Fundamentals of Power Integrity: Self-aggression Noise

Fig. 1: VRM-switching noise is a self aggressor that can be identified because it is synchronous with the PWM clock.
Fig. 1: VRM-switching noise is a self aggressor that can be
identified because it is synchronous 
with the PWM clock. 
Self-aggression noise is so-called because it is inflicted by a component onto itself through its normal operation; nothing else in the system is affecting it. When we look for this, we want to ensure the system is in a steady state, in a place where the noise environment is fairly clear (e.g., the device is on an evaluation board).

An example of self-aggression would be VRM-switching noise. Figure 1 shows ripple on a 900 millivolt rail (yellow trace) at a time when no load is present. One of the things that tells us this is switching noise is that it is synchronous to the PWM clock (red trace). Ripple that is synchronous with the switching clock is a typical figure of merit for identifying switching noise.

31 August 2020

Fundamentals of Power Integrity: Characterizing PDN Noise

Figure 1. Noise tolerances for embedded system components are becoming ever tighter.
Figure 1. Noise tolerances for embedded system
components are becoming ever tighter.
Power integrity concerns maintaining the quality of power from generation to consumption in an embedded system. “Good” power integrity could be defined as having noise levels that are within tolerance. This short series will focus on characterizing noise on your power delivery network (PDN), with the goal of knowing where you must adjust your design to meet those tolerances.

Why do we care about voltage rail noise? As electronic designs strive for ever lower power consumption, power rails already carry very low voltages, often 1 V or less. Components like RF receivers, ADCs and DACs can be affected by noise of less than 1% of the rail value (Figure 1). This means noise tolerances can be as tight as single-digit millivolts, which is why power integrity takes up considerable validation time in labs.

22 January 2018

Power-Rail Noise: Small Signal, Big DC Offset

Your scope's vertical adjust has its limits
Figure 1: Your
scope's vertical
adjust has its
limits
We've been working through the various challenges in making power-rail noise measurements. One of those challenges is RF pickup that can often swamp the noise signal, and the way around that is to ensure a coaxial connection from the oscilloscope's input down to the power rail itself. We want a high signal-to-noise ratio (SNR), so we're better off with a 1X probe than with a 10X attenuating probe. We want high bandwidth, so we want a 50-Ω termination at the oscilloscope input.

18 January 2018

How 10X Attenuating Probes Kill Signal-to-Noise Ratio

Figure 1: Signal waveforms captured using a 10X attenuating
probe (top) and a BNC probe (bottom) with tips open
We've begun discussing things that can derail (see what we did there?) your power-rail measurements, such as the deleterious effects of RF interference. In the same context, one should always be mindful of certain characteristics of oscilloscope probes; namely, the 10X attenuating probes that are often lying around on the testbench.

Understand RF Pickup When Measuring Power Rails

Teledyne LeCroy's  HDO8108A sports a very low  noise floor of about 145 μV
Figure 1: Teledyne LeCroy's
HDO8108A sports a very low
noise floor of about 145 μV 
Measuring the noise on a power rail seems to be a straightforward task. However, there are some basic pitfalls that can cause incorrect, or even downright strange, results. Let's look at one of these challenges: RF pickup. We'll demonstrate the effect of RF pickup on a power-rail measurement, and then we'll show you an effective means of mitigating that effect.

30 October 2017

The Power Integrity Measurement Mindset

power integrity measurement logic wheel
Figure 1:  The holistic view
of power integrity
In kicking off a series of posts on power integrity measurements, it might be helpful to start with some thoughts on the mindset, or approach, that one should take in the endeavor. Power integrity is best approached holistically, with an eye toward each of the paths energy may take throughout a system.