25 April 2022

Setting Up Your Oscilloscope for EFT Testing

Figure 1: The typical EFT test signal consists of multiple exponential pulses arranged as pulse bursts.
Figure 1: The typical EFT test signal consists of
multiple exponential pulses arranged as pulse bursts.
A third type of electromagnetic compatibility (EMC) testing deals with how devices respond to electrical fast transients (EFT). EFTs are a series of fast, high frequency pulses, often occurring in bursts. These transient events are the result of electrical arcing. EFT pulse bursts occur when a power connection is made or broken, equipment is powered down or circuit breakers are switched. They also occur when inductive loads such as relays, switch contactors or heavy-duty motors produce bursts of narrow high-frequency transients on the power distribution system when de-energized.

The typical compound waveform used for EFT testing is shown in Figure 1.

Figure 2: Acquisition of two EFT bursts at 1.25 GS/s, zoomed to show several timing epochs.
Figure 2: Acquisition of two EFT bursts at
1.25 GS/s, zoomed to show several timing epochs.
The pulse waveform for EFT testing is defined by a risetime of 5 ns and a pulse width of 50 ns. These pulses are combined into bursts of 5 to 50 pulses spaced at from 10 to 100 µs (10 to 100 kHz). The bursts are typically spaced as much as 300 ms apart. Figure 2 shows an EFT test signal, with two EFT bursts captured by an oscilloscope on channel 2 sampled at 1.25 GS/s.

The two EFT pulse burst are shown in the upper left-hand trace (the two pink blocks). A series of zoom-on-zoom traces are opened to show several timing epochs. Trace Z2 (second from top left) shows a single burst. The zooms keep expanding the horizontal scale until finally at Z8 (bottom right) we see a single EFT pulse.

Following are six, important things to do to make sure you get the best EFT test measurements from your oscilloscope.

18 April 2022

Setting Up Your Oscilloscope for Surge Testing

Figure 1: A typical EMC surge test waveform with 1.2 µs rise time and 50 µs half amplitude time. Zoom trace Z1 shows the details of the rise time. Click any image to expand it.
Figure 1: A typical EMC surge test waveform with
1.2 µs rise time and 50 µs half amplitude time.
Zoom trace Z1 shows the details of the rise time.
Click any image to expand it.
Electrical surges result from phenomena like lightning strikes and switching transients.  Electronic devices are subjected to simulated surges to confirm that they continue to operate properly following a surge, just as they are tested against electrostatic discharge. 

Surge pulses are similar to ESD pulses in that they have a very fast rise time, but the fall time is much, much slower. Figure 1 shows a typical surge pulse waveform. Surge testing involves similar measurements to those made for  ESD pulse testing—such as rise time, pulse width and max—but surge testing also requires some additional measurements, such as area under the pulse curve and transmitted charge. 

Figure 2: To verify the surge generator waveform, the oscilloscope is connected to the generator through an attenuator.
Figure 2: To verify the surge generator waveform, the
oscilloscope is connected to the generator through an attenuator.
As with ESD pulse tests, oscilloscopes are primarily used to “test the tester,” confirming the output of the surge generator. So, before a surge generator is hooked up to the device under test, it's required to hook it up to an oscilloscope and conduct a series of measurements to make sure the surge pulse is within specification. Figure 2 shows a typical surge test setup.

Following are three, important things to do to make sure you get the best surge measurements from your oscilloscope.

11 April 2022

Setting Up Your Oscilloscope for ESD Pulse Testing

Figure 1: An ESD calibration test setup.  The ESD gun discharges its waveform into a properly attenuated current target.
Figure 1: An ESD calibration test setup. 
The ESD gun discharges its waveform
into a properly attenuated current target. 
Electrostatic discharge (ESD) pulse tests are a type of conducted immunity testing done to confirm that a device can withstand a sudden transient electrostatic discharge. It is done by using an ESD gun to shoot a pulse of the required voltage at a device while testing that the DUT continues to operate properly. The ESD pulse shape simulates a person, carrying a static charge, touching a device. When their fingertip first touches the device, there is a leading edge with a high peak and fast decay, often visible in the real world as a spark flying from the fingertip. This is followed by a second edge due to the charge in the rest of the human body that propagates toward the fingertip with a time delay.

Oscilloscopes are most often used to “test the tester” in ESD pulse test setups, confirming that the pulse from the ESD gun is the right shape and meets the requirements of the standard to which the device is being tested. A typical calibration test setup is shown in Figure 1. The pulse from the ESD gun is fired directly into a current shunt target connected to the oscilloscope through an attenuator required to keep the signal within the limits of the oscilloscope’s 50 Ω input, which is used for this testing. Then, key parameters of the ESD pulse are measured per one of several standards, such as IEC 61000-4-2.  

ESD standards require a range of measurements. The most common are the initial edge 10% to 90% rise time, peak amplitude, pulse width, amplitude and current levels at specified times from the initial edge (e.g., T1 and T2), and time to half value. 

Following are four, important things to do to make sure you get the best ESD pulse measurements from your oscilloscope.

30 October 2017

The Power Integrity Measurement Mindset

power integrity measurement logic wheel
Figure 1:  The holistic view
of power integrity
In kicking off a series of posts on power integrity measurements, it might be helpful to start with some thoughts on the mindset, or approach, that one should take in the endeavor. Power integrity is best approached holistically, with an eye toward each of the paths energy may take throughout a system.

26 July 2017

The Periodic Table of Oscilloscope Tools: Analyze (Part III)

Periodic Table
We're nearing the end of our tour of the Periodic Table of Oscilloscope Tools, our way of presenting our broad palette of oscilloscope tools in a concise, clear fashion. In this installment, we'll finish up the Analyze grouping, by far the largest on the Periodic Table.

30 September 2016

Dynamic Range, Signal Integrity, and ESD Pulses

Use your oscilloscope's full vertical range to take full advantage of the ADC's resolution
Figure 1: Use your oscilloscope's full vertical range to
take full advantage of the ADC's resolution
Having considered the impact of sampling rate on ESD pulse measurements, let's now turn our attention to dynamic range and signal integrity. No matter what oscilloscope you use, it's important to make the most of the instrument's full vertical range to achieve maximum accuracy.

28 September 2016

How Does Sampling Rate Affect ESD Pulse Measurements?

Characterization of an ESD pulse's rise time depends largely on the oscilloscope's sampling rate
Figure 1: Characterization of an ESD pulse's rise time
depends largely on the oscilloscope's sampling rate
In continuing our look at ESD/EMC pulse measurements, it would be useful to consider how sampling rate figures into the equation. What sort of sampling rate makes sense to use for capturing an ESD pulse? The answer to that question depends primarily on your pulse's rise time.

13 September 2016

Why IEEE's Pulse Definitions and ESD Pulses Don't Mix

The IEEE's pulse definitions, which don't fit the bill for measuring ESD pulses
Figure 1: The IEEE's pulse definitions, which don't fit
the bill for measuring ESD pulses
The IEEE's pulse definitions, found in the organization's Std 181-2011 that covers transitions, pulses, and related waveforms, set the bar for how pulse measurements are determined. These definitions, which are in the DNA of all oscilloscopes, are just the thing for measuring repetitive pulses such as clock signals but not so much for ESD/EMC measurement requirements. In this post, we'll discuss why that is and what you should do differently for measuring ESD pulses.

30 August 2016

Making EMC/ESD Pulse Measurements

Four quadrants of EMC/ESD testing
Figure 1: Oscilloscopes are used for
testing in the green-shaded boxes
There are many circumstances in which electromagnetic compatibility (EMC) and electrostatic discharge (ESD) testing are a fact of life. Many countries have adopted IEC international standards that dictate certain levels of immunity, as have the automotive, medical, military, and aerospace industries. In this post, we'll begin looking at how oscilloscopes figure into tests for both radiated and conducted EMC/ESD immunity.