New 60 V Offset Power Rail Probes Offer the Capability Needed for 48 V Power Integrity Analysis

RP4060 Rail Probe
Figure 1. The RP2060 and RP4060
build on the legacy of the RP4030 power
rail probe. The new probes are ideally
suited to working with the new 48 Vdc 
power structures.
In 2016, Teledyne LeCroy first offered the RP4030 Power Rail Probe, which was designed to enable engineers to probe a low-impedance, low-voltage DC power/voltage rail signal without loading the device under test (DUT). It provided ±30 V of probe offset to allow a DC power/voltage rail signal to be displayed in the vertical center of the oscilloscope regardless of the gain (sensitivity) setting.

Recently, we released two, new power rail probes that build on those capabilities—the 2 GHz RP2060 and 4 GHz RP4060. Both probes feature:

  • ±60 V Offset Capability
  • ±800 mV Dynamic Range
  • 50 kΩ DC Input Impedance (for low loading of low-impedance power rails)
  • 1.2:1Attenuation (for low additive noise)
  • MCX-terminated cable with a variety of board connections: 4 GHz*-rated MCX PCB mount;
    4 GHz* solder-in; 3 GHz* coaxial cable to U.FL PCB mount; optional 500 MHz browser
* Bandwidths listed are for the 4 GHz RP4060. Maximum bandwidth when used with RP2060 is 2 GHz.

Why the New Probes?

One driver of the new release is the increase in the number and size of data centers needed to support cloud computing and other data-intensive applications, and the new power architectures they require. The new rail probe is designed to ideally meet the needs of engineers working with power rails rated up to 48 Vdc.

20 September 2021

Testing Power Rail Sequences in Complex Embedded Systems

Figure 1. Four power rail signals on a single grid, with cursors measuring the time delay between the first pair in the sequence.
Figure 1. Four power rail signals on a single grid, with cursors
measuring the time delay between the first pair in the sequence.
Embedded computing systems generally require multiple supply voltages to deliver power to the microprocessor, memory and other on-board devices. There is usually a 12- or 15-volt DC primary supply, and numerous buck or boost converters working off the primary to help provide various voltages throughout the embedded system. Most microcontrollers have a prescribed order in which the voltages must be applied to prevent problems like lockups, so an area of concern when designing deeply embedded systems is the proper sequencing of power rails as they power up or down. Power management IC’s (PMIC) or power sequencers perform many of the sequencing tasks, but during validation and when troubleshooting, the order and timing of the power sequence should be verified.

30 August 2021

Debugging Complex Embedded Systems

Figure 1: A typical embedded system has many devices utilizing a wide range of signal types and bandwidths.
Figure 1: A typical embedded system has many devices
utilizing a wide range of signal types and bandwidths.
In the next few weeks, we’ll present a series of posts describing the debugging of various components of embedded systems, everything from working out the timing of power on sequences to extracting analog sensor data from serial data streams. All these examples of “real world” debugging can be performed using only standard tools available on most mid-range Teledyne LeCroy oscilloscopes.

Let's start by defining what we mean by embedded system and deeply embedded system. For our purposes, an embedded system is a fixed function, self-contained control system on one printed circuit board. Typically, printed circuit boards (PCBs)  will have multiple passive devices, a few active electronic devices, analog devices, digital devices and a few serial data devices. There tends to be a microcontroller device to process data and control other components. There will also be some type of system memory, often embedded inside the microcontroller. And, there will be some power conversion devices and power distribution elements that power all the other devices in your embedded system. 

08 February 2021

Using Spectrograms to Visualize Spectral Changes

Figure 1. The spectrogram shows a history of change in a spectrum and highlights variations in frequency or amplitude.
Figure 1. The spectrogram shows a history of
change in a spectrum and highlights variations
in frequency or amplitude.

In our last post, we discussed spectral analysis of RF in the lab as part of developing situational awareness. Another tool for spectral analysis is the spectrogram.

The spectrogram is a display composed of the most recently acquired 256 spectra all stacked in a persistence display. It is a feature of the SPECTRUM-1 and SPECTRUM-PRO-2R options that highlights variations in acquired spectra, making dynamic changes immediately visible. 

The spectrogram in Figure 1 shows the timing dynamics of a power rail load variation in a three-dimensional (3D) plot with color persistence. The same data could also be rendered in a flat, two-dimensional (2D) spectrogram display, or using monochrome instead of color persistence.