You need to test, we're here to help.

You need to test, we're here to help.
Showing posts with label common mode. Show all posts
Showing posts with label common mode. Show all posts

24 May 2021

Mode Conversion

Figure 1: The lower-left and upper-right quadrants of this matrix show the S-parameters that represent mode conversion from differential to common signal, and vice versa.
Figure 1: The lower-left and upper-right quadrants of this
matrix show the S-parameters that represent mode conversion
from differential to common signal, and vice versa.
As said earlier, mixed-mode S-parameters describe the general case of combinations of differential and common signals. When we speak of mode conversion in mixed-mode S-parameters, we are referring to the change of a differential signal into a common signal, or a common signal into a differential signal, as it travels the transmission line. If we look at the matrix of mixed-mode S-parameters in Figure 1, we see that those mixed mode S-parameters affected by such a mode conversion—with a different type of signal going out than what went in—are in the lower-left and upper-right quadrants.  

Let’s take the S-parameters SCD11 and SCD21 to see how the combination of single-ended S-parameters they represent reveal the source of mode conversion. If we look at SCD11, the reflected mode conversion, as a function of its single-ended S-parameters, we see:

06 February 2018

Probing Techniques and Tradeoffs (Part VII): More on Dynamic Range

Input offset range is how much differential offset a probe can apply to an input signal to bring it within its differential-mode output range
Figure 1: Input offset range is how much
differential offset a probe can apply to
an input signal to bring it within its
differential-mode output range
In our last post in this series, we'd begun discussing the third of three types of dynamic range as applied to probes, and that is input offset range. This is the maximum differential offset that a probe can apply to the input signal to bring it within the probe's differential-mode dynamic range.

04 January 2018

Probing Techniques and Tradeoffs (Part VI): Dynamic Range

Differential-mode dynamic range is the maximum allowable voltage between the probe amplifier's inputs
Figure 1: Differential-mode dynamic range is the maximum
allowable voltage between the probe amplifier's inputs
We've been discussing probe loading, which is the unavoidable reality of what happens when you attach an oscilloscope probe to a live circuit. We'll now shift the discussion to dynamic range, an important topic that can be overlooked when selecting an oscilloscope probe. There are three types of dynamic range that one should understand. Each of them will influence how you set up your probe and how you set up your signal under test to most effectively get that signal into the oscilloscope's front-end amplifier.

12 December 2013

Back to Basics: Probes (Part IV)

An example of differential probes
Figure 1: An example of
differential probes
measuring from test
point to test point.
In three earlier posts on the basics of oscilloscope probes, we've taken a broad overview approach, looked more deeply at passive probes and inductance effects, and most recently, dug into active probes. Next up is differential probes, a different animal entirely from the foregoing types.

23 July 2013

Back to Basics: Differential Probing

Emitter voltage in simplified schematic
Figure 1: Emitter voltage measurement
in simplified schematic view
Whether or not we think of it in such terms, any voltage measurement taken with an oscilloscope or voltmeter is, in reality, a differential voltage measurement. A voltage is, by definition, the difference in electrical potential between two points in a circuit. It's impossible to take a voltage measurement with only one voltmeter lead. One lead must be attached to the point of interest while the other must be connected somewhere else as a reference point.