Figure 1. A 100 MHz sine wave in the time domain and its spectrum in the frequency domain showing the one peak at 100 MHz. Click on any image to enlarge. |
Teledyne LeCroy Fellow
The following piece was published in Signal Integrity Journal and is excerpted here by permission of Signal Integrity Journal.
***************************
We live in the time domain. This is where we measure all digital performance. But sometimes, we can get to an answer faster by taking a detour through the frequency domain. With these six principles, we can understand how an oscilloscope transforms time domain measurements into a frequency domain view. All six principles are applied “under the hood” by oscilloscopes with a built-in FFT function. (Our note: Also by software packages designed for spectral analysis, such as the SPECTRUM-1 and SPECTRUM-PRO-2R options.)
1. The spectrum is a combination of sine wave components
In the frequency domain, the only waveforms we are allowed to consider are sine waves. There are other special waveforms combinations of which can describe any time-domain waveform, such as Legendre polynomials, Hermite polynomials or even wavelets. The reason we single out sine waves for a frequency domain description, is that sine waves are solutions to second order, linear, differential equations—the equations found so often in electrical circuits involving resistor, capacitor and inductor elements. This means signals that arise or have interacted with RLC circuits are described more simply when using combinations of sine waves than any other function because sine waves naturally occur.
A sine wave measured by an oscilloscope with 1 million voltage-time [V(t)] data points in the acquisition buffer (Figure 1) is described by only three numbers in the frequency domain: a frequency value, an amplitude value and a phase value. This is a dramatic simplification of the original complex waveform.
2. Appending a waveform to itself infinitely creates a periodic waveform
When we take a waveform in the time domain and transform it into the frequency domain, we end up with a collection of sine waves, each with a frequency value, an amplitude and a phase. In the time domain, we describe the measurements as an acquisition buffer with a total acquisition time, T, and a time interval between samples, 𝛥T. When we describe the same waveform in the frequency domain, we refer to the collection of all the sine wave components—each with a frequency, amplitude and phase—as the spectrum.
Unfortunately, we can only use the Discrete Fourier Transform (DFT) on a V(t) waveform that is periodic. If it is not periodic, we must artificially make it periodic. The trick we use to turn any arbitrary acquisition buffer of measured data into a periodic waveform is to take the acquisition buffer of total time, T, and repeat it forever in the past and forever in the future.
When we have this artificially repetitive waveform, we can apply the power of the DFT to mathematically calculate each frequency component in the spectrum. Here are the equations used to calculate the amplitude and phase of each frequency component:
These integrals create certain features in the spectrum.
3. Only discrete frequencies appear in a spectrum; the lowest is the fundamental
In the calculated spectrum, only discrete frequency values appear. The lowest frequency component is called the fundamental. It is the lowest frequency sine wave we can fit into the acquisition buffer time. The period, P, of this lowest frequency sine wave is the total acquisition time, T.
Since P equals T, the fundamental frequency is:
Each frequency component in the spectrum has a frequency that is only an integer multiple of the fundamental:
Multiples of the fundamental are the only frequency components we will see in the spectrum. This means, the frequency spacing between each frequency component, or the resolution, is the fundamental frequency. If we want a higher resolution to distinguish closer spaced frequency features in the spectrum, we need to use a longer acquisition time in the oscilloscope.
4. The highest frequency is the Nyquist, or one-half the sample rate
The highest frequency component in the spectrum is related to the time interval between the sampled points in the buffer. At a minimum, we need two measured V(t) points in one period in order to calculate a value for the amplitude and phase of that frequency component. This means the period of the highest frequency sine wave we can calculate is twice the time interval, or Pmax = 2 x 𝛥T.
The highest frequency component in the spectrum is also referred to as the Nyquist frequency. Since the sample rate for taking data is 1/𝛥T, the Nyquist frequency, the highest frequency for which we can calculate a sine wave component is one-half the sample rate. If the sample rate is 10 GS/s, the Nyquist frequency is 5 GHz.
The average value of an ideal sine wave is always 0. This means that when we use a collection of sine waves to describe a real waveform, the average value of the recreated time-domain waveform is always 0. But real waveforms have an average value, or DC offset. To account for this, we store the DC component in the 0 Hz frequency component, which is 0 x the fundamental. On most oscilloscopes, you can suppress plotting the 0th frequency component to zoom in on the scale of the display.
5. The FFT speeds calculation by truncating the buffer to 2^n sample points
One million data points would involve about 1 trillion DFT calculations to create one spectrum. This make take longer to calculate than is convenient. To get around this problem, we use a much faster version of the DFT called the Fast Fourier Transform (FFT). It calculates the same integrals as the DFT, but it applies matrix math to perform the calculations using a total number of points that is a power of 2. If there are 1 million points in the buffer, the highest number of points that could be included in the FFT calculation would be 2^19 = 524,288 points. We throw out almost half the measured data to gain incredibly fast computation time.
Figure 2 Between the vertical dashed lines is the region of the acquisition buffer that contains the 2^n points which will be used in the FFT. |
When the acquisition buffer time is 1 µs, and we have 1 million points, we expect the fundamental to be 1 MHz. In the spectrum, the FFT acquisition buffer is smaller than this, which means the actual resolution is slightly larger than 1 MHz. But these estimates are still a good value to use when thinking about the features of the spectrum.
6. Windowing functions prevent spectral leakage due to the truncation
Normally, the spectrum of a sine wave that has an integral number of cycles in each buffer will have a single spike at its peak frequency. However, if the sine wave is artificially cut off due to the truncated acquisition buffer, the infinitely long waveform will now have a discontinuity that will force some of the frequency components from the peak frequency into adjacent frequency components, which can result in a distortion of the narrow peak.
This effect is called spectral leakage. It is an artifact of the discontinuity at the boundaries of the buffers due to the first voltage value not being the same as the last voltage value. The way to reduce this artifact is to artificially reduce the discontinuity by multiplying the entire acquisition buffer by a window function. This gradually forces the voltage value at the ends of the acquisition buffer to be 0, guaranteeing that the end of one buffer is continuous with the beginning of the next buffer.
There are a number of windowing functions commonly used. They differ in how much spectral leakage they allow and the resulting resolution. Unless you have a strong compelling reason, we recommend that you always use either the von Hann (sometimes called Hanning) or the Blackman-Harris function.
Analyzing Time Domain Waveforms in the Frequency Domain
The value of spectral analysis is being able to identify the spectral “fingerprint” of repetitive signals with frequencies that fit within the range between the fundamental (1/acquisition buffer) and the Nyquist (½ x sample rate). Each time the oscilloscope measures a new acquisition buffer of time-domain voltages, the newly calculated spectral response is displayed. As periodic signals in the source change, their spectral fingerprint changes.
Figure 4. The real-time spectrum of a SMPS output while the output load is changing showing the time variation of the peak frequencies. |
Figure 5. Measured real-time spectrum of the noise from a USB power rail showing large components in the FM radio band from pick up in the probe. |
To learn more about this topic, view this free webinar by Prof. Eric Bogatin, Understanding Real-time Spectral Analysis.
Also see:
About Data Truncation in Fast Fourier Transforms
No comments: