Is It OK to Use an External 50 Ohm Terminator with an Oscilloscope?

Recently, a reader posed the question in the Comment field on Dr. Eric Bogatin's blog post, How to Choose Between the Oscilloscope's 50 Ohm Input and 1 MOhm Input:  "Is there any difference between using an external 50 Ohm terminator instead of the internal 50 Ohm termination on the oscilloscope--for example, using a RG58/RG174 cable?"

Eric answered:

"In principle, you can use the oscilloscope input set for 1 MOhm termination, then add an external 50 Ohm termination resistor on a BNC Tee connector, for example. This has the advantage that you can actually use any resistor for a load, or terminate signals with an RMS voltage larger than 5 V.

However, there are two problems with using this approach for high-speed signals with rise times shorter than 1 nsec, which require an oscilloscope with bandwidth larger than 1 GHz.

19 October 2020

Which Virtual Probing Method to Use?

 

Virtual probing lets you "probe" where a probe can't reach, or compensate signals by deembedding or simulating devices and channels.
Virtual probing lets you "probe" where a probe
can't reach, or compensate signals by deembedding
or simulating devices and channels.
A great feature of Teledyne LeCroy oscilloscopes is the ability to apply virtual probing to compensate an input signal, whether by deembedding fixtures from the signal path, or simulating a “missing” component. It is especially helpful in cases where the signal is difficult to probe at the ideal location, hence the concept of “virtual” probing.

For example, because the JEDEC electrical specifications are defined at the balls of the DDR DRAM, it is often necessary to use the virtual probing capabilities of the oscilloscope to get the best representations of DDR signals to be analyzed with DDR Debug Toolkit or QualiPHY compliance software.

Here, we’ll give an overview of the virtual probing methods that become available with the installation of the SDAIII-CompleteLinQ or VirtualProbe software options, and some guidance as to which method is best to use in which case. And although we’ll show examples drawn from DDR analysis, the benefits of virtual probing are by no means limited to DDR signals.