13 June 2018

Inter-Symbol Interference (or Leaky Bits)

Inter-symbol interference, or ISI jitter, is the result of information from one bit "leaking" to subsequent bits
Figure 1: Inter-symbol interference, or ISI jitter, is the result
of information from one bit "leaking" to subsequent bits
In reviewing the subject of debugging high-speed serial links, one important aspect of signal integrity we must touch on is inter-symbol interference (ISI). ISI is the phenomenon in which information from one bit "leaks" to some subsequent number of bits.

18 April 2016

The Evolving User Interface: Changing Sources

Changing the source of a trace is as simple as a drag-and-drop of the desired source's descriptor box onto the target descriptor box
Figure 1: Changing the source of a trace is as simple as
a drag-and-drop of the desired source's descriptor box onto
the target descriptor box
A truly modern oscilloscope user interface should lend itself to free-form experimentation in the interest of design and debug. Impulses to "try something" are at the core of creativity; you never want your test bench to stifle them. It should stay out of your way and not force you to stop and think about how to interact with the oscilloscope to make "something" happen. That's what Teledyne LeCroy has achieved by augmenting its MAUI - Most Advanced User Interface with OneTouch gesture control, a set of drag-and-drop actions that bring even more intuitiveness and flexibility to oscilloscopes' touchscreens (we covered another feature, Copy Setup, in an earlier post).